| Active Filters |
| | | | | | | | | | | | | | |
| 122191 | | | | Anthracite | Measured | N2O emission factor for sintering furnace in iron industry | sintering furnace for iron making | Load during measurement about 80% -100%, Flue gas(dry) : O2 13.5%, CO2 6.68%, CO 6982.0ppm | Republic of Korea | | | 2.275 | kg/TJ | Other | |
| 122192 | | | | Anthracite | Measured | CH4 emission factor for sintering furnace in iron industry | sintering furnace for iron making | Load during measurement about 80% -100%, Flue gas(dry) : O2 13.5%, CO2 6.68%, CO 6982.0ppm | Republic of Korea | | | 66.46 | kg/TJ | Other | |
| 122193 | | | | Coke Oven Coke and Lignite Coke | Measured | N2O emission factor for combustion facilities for cupola of cast iron | cupola for cast iron | Load during measurement about 60% -100%, Flue gas(dry) : O2 12.1-13.4%, CO2 2.23-4.29%, CO 225.20-273.20ppm | Republic of Korea | | | 2.724 | kg/TJ | Other | |
| 122194 | | | | Coke Oven Coke and Lignite Coke | Measured | CH4 emission factor for combustion facilities for cupola of cast iron | cupola for cast iron | Load during measurement about 60% -100%, Flue gas(dry) : O2 12.1-13.4%, CO2 2.23-4.29%, CO 225.20-273.20ppm | Republic of Korea | | | 41.963 | kg/TJ | Other | |
| 122195 | | | | Natural Gas | Measured | N2O emission factor for combustion facilities for reheating furnace | Steel reheating furnace with the pusher or walking beam type | Load during measurement about 60% -100%, Flue gas(dry) : O2 6.90-9.94%, CO2 7.88-8.33%, CO 52.3-107.01ppm | Republic of Korea | | | 0.376 | kg/TJ | Other | |
| 122196 | | | | Natural Gas | Measured | CH4 emission factor for combustion facilities for reheating furnaces | Steel reheating furnace with the pusher or walking beam type | Load during measurement about 60% -100%, Flue gas(dry) : O2 6.90-9.94%, CO2 7.88-8.33%, CO 52.3-107.01ppm | Republic of Korea | | | 0.235 | kg/TJ | Other | |
| 122197 | | | | Residual Fuel Oil | Measured | N2O emission factor for combustion facilities for reheating furnace | Steel reheating furnace with the pusher or walking beam type | Load during measurement about 60% -100%, Flue gas(dry) : O2 8.86-12.2%, CO2 8.06 - 10.31%, CO 86.8 -121.84ppm | Republic of Korea | | | 0.377 | kg/TJ | Other | |
| 122198 | | | | Residual Fuel Oil | Measured | CH4 emission factor for combustion facilities for reheating furnaces | Steel reheating furnace with the pusher or walking beam type | Load during measurement about 60% -100%, Flue gas(dry) : O2 8.86-12.2%, CO2 8.06 - 10.31%, CO 86.8 -121.84ppm | Republic of Korea | | | 0.531 | kg/TJ | Other | |