| Active Filters |
| | | | | | | | | | | | | | |
| 122265 | - 1A2f - Other (please specify)
| - 1.A.2.g - Transport Equipment
| | Natural Gas | Measured | N2O emission factor for industrial boiler | industrial boiler for flue tube & water tube type | Load during measurement about 60% -100%, Flue gas(dry) : O2 4.41-4.83%, CO2 9.85-10.04%, | Republic of Korea | | | 0.413 | kg/TJ | Other | |
| 122266 | - 1A2f - Other (please specify)
| - 1.A.2.g - Transport Equipment
| | Natural Gas | Measured | CH4 emission factor for industrial boiler | industrial boiler for flue tube & water tube type | Load during measurement about 60% -100%, Flue gas(dry) : O2 4.41-4.83%, CO2 9.85-10.04%, | Republic of Korea | | | 0.251 | kg/TJ | Other | |
| 122267 | - 1A2f - Other (please specify)
| - 1.A.2.g - Transport Equipment
| | Residual Fuel Oil | Measured | N2O emission factor for industrial boiler | industrial boiler for flue tube type | Load during measurement about 80%, Flue gas(dry) : O2 4.32%, CO2 12.93%, | Republic of Korea | | | 0.96 | kg/TJ | Other | |
| 122268 | - 1A2f - Other (please specify)
| - 1.A.2.g - Transport Equipment
| | Residual Fuel Oil | Measured | CH4 emission factor for industrial boiler | industrial boiler for flue tube type | Load during measurement about 80%, Flue gas(dry) : O2 4.32%, CO2 12.93%, | Republic of Korea | | | 0.012 | kg/TJ | Other | |
| 122269 | - 1A2f - Other (please specify)
| - 1.A.2.g - Transport Equipment
| | Diesel Oil | Measured | N2O emission factor for industrial boiler | industrial boiler for flue tube type | Load during measurement about 90%, Flue gas(dry) : O2 8.17%, CO2 9.63%, | Republic of Korea | | | 1.415 | kg/TJ | Other | |
| 122270 | - 1A2f - Other (please specify)
| - 1.A.2.g - Transport Equipment
| | Diesel Oil | Measured | CH4 emission factor for industrial boiler | industrial boiler for flue tube type | Load during measurement about 90%, Flue gas(dry) : O2 8.17%, CO2 9.63%, | Republic of Korea | | | 0.017 | kg/TJ | Other | |