| Active Filters |
| | | | | | | | | | | | | |
| 214351 | - 2F6 - Other (please specify)
| - 2.F.2 - Foam Blowing Agents
| - HFE-245fa1
- HFE-365mcf3
- HFC-134a
- HFC-152a
- HFC-227ea
| 1996 & 2006 IPCC default | Product Lifetime (n), First Year Losses (FYL) and Annual Losses (AL) for HFC emissions from Closed-Cell Foam | | Foam Type: Closed-cell foam | | | | n = 20 years; FYL = 10; AL = 4.5 | % of the original HFC charge/year | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 7, Table 7.5); IPCC Good Practice Guidance and Uncertainty Management in National Greenhouse Gas Inventories (Chapter 3, Table 3.17, Page 3.96) | |
| 214356 | - 2F6 - Other (please specify)
| - 2.F.2 - Foam Blowing Agents
| | 2006 IPCC default | Product Lifetime (n), First Year Loss (FYL), Annual Loss (AL) and Maximum Potential End-of-Life Loss (EOLL) for HFC emissions from Foam Blowing | | Sub-application type: Polyurethane - Integral Skin | | | | n = 12 years; FYL = 95; AL = 2.5; EOLL = 0 | % | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 7, Table 7.6) | |
| 214357 | - 2F6 - Other (please specify)
| - 2.F.2 - Foam Blowing Agents
| | 2006 IPCC default | Product Lifetime (n), First Year Loss (FYL), Annual Loss (AL) and Maximum Potential End-of-Life Loss (EOLL) for HFC emissions from Foam Blowing | | Sub-application type: Polyurethane - Continuous Panel | | | | n = 50 years; FYL = 10; AL = 0.5; EOLL = 65 | % | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 7, Table 7.6) | |
| 214358 | - 2F6 - Other (please specify)
| - 2.F.2 - Foam Blowing Agents
| | 2006 IPCC default | Product Lifetime (n), First Year Loss (FYL), Annual Loss (AL) and Maximum Potential End-of-Life Loss (EOLL) for HFC emissions from Foam Blowing | | Sub-application type: Polyurethane - Discontinuous Panel | | | | n = 50 years; FYL = 12.5; AL = 0.5; EOLL = 62.5 | % | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 7, Table 7.6) | |
| 214359 | - 2F6 - Other (please specify)
| - 2.F.2 - Foam Blowing Agents
| | 2006 IPCC default | Product Lifetime (n), First Year Loss (FYL), Annual Loss (AL) and Maximum Potential End-of-Life Loss (EOLL) for HFC emissions from Foam Blowing | | Sub-application type: Polyurethane - Appliance | | | | n = 15 years; FYL = 7; AL = 0.5; EOLL = 85.5 | % | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 7, Table 7.6) | |
| 214360 | - 2F6 - Other (please specify)
| - 2.F.2 - Foam Blowing Agents
| | 2006 IPCC default | Product Lifetime (n), First Year Loss (FYL), Annual Loss (AL) and Maximum Potential End-of-Life Loss (EOLL) for HFC emissions from Foam Blowing | | Sub-application type: Polyurethane - Injected | | | | n = 15 years; FYL = 12.5; AL = 0.5; EOLL = 80 | % | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 7, Table 7.6) | |
| 214361 | - 2F6 - Other (please specify)
| - 2.F.2 - Foam Blowing Agents
| | 2006 IPCC default | Product Lifetime (n), First Year Loss (FYL), Annual Loss (AL) and Maximum Potential End-of-Life Loss (EOLL) for HFC emissions from Foam Blowing | | Sub-application type: One Component Foam (OCF) | | | | n = 50 years; FYL = 95; AL = 2.5; EOLL = 0 | % | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 7, Table 7.6) | |
| 214362 | - 2F6 - Other (please specify)
| - 2.F.2 - Foam Blowing Agents
| | 2006 IPCC default | Product Lifetime (n), First Year Loss (FYL), Annual Loss (AL) and Maximum Potential End-of-Life Loss (EOLL) for HFC emissions from Foam Blowing | | Sub-application type: Extruded Polystyrene (XPS) | | | | n = 50 years; FYL = 25; AL = 0.75; EOLL = 37.5 | % | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 7, Table 7.6) | |
| 214363 | - 2F6 - Other (please specify)
| - 2.F.2 - Foam Blowing Agents
| | 2006 IPCC default | Product Lifetime (n), First Year Loss (FYL), Annual Loss (AL) and Maximum Potential End-of-Life Loss (EOLL) for HFC emissions from Foam Blowing | | Sub-application type: Extruded Polyethylene (PE) | | | | n = 50 years; FYL = 40; AL = 3; EOLL = 0 | % | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 7, Table 7.6) | |
| 214370 | - 2F6 - Other (please specify)
| - 2.F.2 - Foam Blowing Agents
| | 2006 IPCC default | Product Lifetime (n), First Year Loss (FYL), Annual Loss (AL) and Maximum Potential End-of-Life Loss (EOLL) for HFC emissions from Foam Blowing | | Sub-application type: Extruded Polystyrene (XPS) | | | | n = 50 years; FYL = 50; AL = 25; EOLL = 0 | % | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 7, Table 7.6) | |
| 214372 | - 2F6 - Other (please specify)
| - 2.F.2 - Foam Blowing Agents
| | 1996 IPCC default | Product Lifetime (n), First Year Loss (FYL) and Annual Loss (AL) for HFC emissions from Foam Blowing | | Sub-application type: Polyurethane - Integral Skin | | | | n = 12-15 years; FYL = 95; AL = 2.5 | % | IPCC Good Practice Guidance and Uncertainty Management in National Greenhouse Gas Inventories (Table 3.18 on Page 3.96) | |
| 214373 | - 2F6 - Other (please specify)
| - 2.F.2 - Foam Blowing Agents
| | 1996 IPCC default | Product Lifetime (n), First Year Loss (FYL) and Annual Loss (AL) for HFC emissions from Foam Blowing | | Sub-application type: Polyurethane - Continuous Panel | | | | n = 50 years; FYL = 10; AL = 0.5 | % | IPCC Good Practice Guidance and Uncertainty Management in National Greenhouse Gas Inventories (Table 3.18 on Page 3.96) | |
| 214374 | - 2F6 - Other (please specify)
| - 2.F.2 - Foam Blowing Agents
| | 1996 IPCC default | Product Lifetime (n), First Year Loss (FYL) and Annual Loss (AL) for HFC emissions from Foam Blowing | | Sub-application type: Polyurethane - Discontinuous Panel | | | | n = 50 years; FYL = 12.5; AL = 0.5 | % | IPCC Good Practice Guidance and Uncertainty Management in National Greenhouse Gas Inventories (Table 3.18 on Page 3.96) | |
| 214375 | - 2F6 - Other (please specify)
| - 2.F.2 - Foam Blowing Agents
| | 1996 IPCC default | Product Lifetime (n), First Year Loss (FYL) and Annual Loss (AL) for HFC emissions from Foam Blowing | | Sub-application type: Polyurethane - Appliance | | | | n = 15-20 years; FYL = 7.5; AL = 0.5 | % | IPCC Good Practice Guidance and Uncertainty Management in National Greenhouse Gas Inventories (Table 3.18 on Page 3.96) | |
| 214376 | - 2F6 - Other (please specify)
| - 2.F.2 - Foam Blowing Agents
| | 1996 IPCC default | Product Lifetime (n), First Year Loss (FYL) and Annual Loss (AL) for HFC emissions from Foam Blowing | | Sub-application type: Polyurethane - Injected | | | | n = 15 years; FYL = 12.5; AL = 0.5 | % | IPCC Good Practice Guidance and Uncertainty Management in National Greenhouse Gas Inventories (Table 3.18 on Page 3.96) | |
| 214377 | - 2F6 - Other (please specify)
| - 2.F.2 - Foam Blowing Agents
| | 1996 IPCC default | Product Lifetime (n), First Year Loss (FYL) and Annual Loss (AL) for HFC emissions from Foam Blowing | | Sub-application type: One Component Foam (OCF) | | | | n = 50 years; FYL = 95; AL = 2.5 | % | IPCC Good Practice Guidance and Uncertainty Management in National Greenhouse Gas Inventories (Table 3.18 on Page 3.96) | |
| 214378 | - 2F6 - Other (please specify)
| - 2.F.2 - Foam Blowing Agents
| | 1996 IPCC default | Product Lifetime (n), First Year Loss (FYL) and Annual Loss (AL) for HFC emissions from Foam Blowing | | Sub-application type: Extruded Polystyrene/Extruded Polyethylene (XPS/PE) | | | | n = 50 years; FYL = 40; AL = 3 | % | IPCC Good Practice Guidance and Uncertainty Management in National Greenhouse Gas Inventories (Table 3.18 on Page 3.96) | |
| 225319 | | - 2.F.2 - Foam Blowing Agents
| | Other (e.g. compiled) | Emission factor for manufacturing | XPS (extruded polystyrene) plates | | Austria | | | 25 (2000-2004) | % | National Inventory Report (Annex I) | |
| 225320 | | - 2.F.2 - Foam Blowing Agents
| | Other (e.g. compiled) | Emission factor for emissions from stock | XPS (extruded polystyrene) plates | | Austria | | | 1.15 (1995-2004) | % | National Inventory Report (Annex I) | |
| 225321 | | - 2.F.2 - Foam Blowing Agents
| | Other (e.g. compiled) | Emission factor for emissions from stock | XPS (extruded polystyrene) plates | | Austria | | | 0.81 (from 2005 on) | % | National Inventory Report (Annex I) | |