| Active Filters |
| | | | | | | | | | | | | |
| 214446 | - 2F6 - Other (please specify)
| - 2.G.1.a - Manufacture of Electrical Equipment
| | 2006 IPCC default | Manufacturing Emission Factor for Emissions from Electrical Equipment (Emission Factor for Manufacturing Phase) | Sealed Pressure Electrical Equipment (MV Switchgear) [MV Switchgear = Medium Voltage Switchgear for rated operating voltages above 1000 Volts and up to 52000 Volts; Based on technologies and practices in place in 1995 | | Europe | No mitigation measures implemented | | 0.07 | fraction [amount of gas emitted per amount of gas consumed] | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.2) | |
| 214447 | - 2F6 - Other (please specify)
| - 2.G.1.b - Use of Electrical Equipment
| | 2006 IPCC default | Equipment Use Emission Factor for Emissions from Electrical Equipment (Emission Factor for Use Phase) | Sealed Pressure Electrical Equipment (MV Switchgear) [MV Switchgear = Medium Voltage Switchgear for rated operating voltages above 1000 Volts and up to 52000 Volts; Based on technologies and practices in place in 1995 | | Europe | No mitigation measures implemented | | 0.002 | fraction [amount of gas emitted per year per nameplate capacity of all equipment | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.2) | |
| 214448 | - 2F6 - Other (please specify)
| - 2.G.1.c - Disposal of Electrical Equipment
| | 2006 IPCC default | Fraction of Charge Remaining at Retirement (Emission Factor for Disposal Phase), and Lifetime of Equipment | Sealed Pressure Electrical Equipment (MV Switchgear) [MV Switchgear = Medium Voltage Switchgear for rated operating voltages above 1000 Volts and up to 52000 Volts; Based on technologies and practices in place in 1995 | | Europe | No mitigation measures implemented | | 0.93 [Lifetime: >35 years] | fraction [amount of gas emitted per nameplate capacity of all equipment installe | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.2) | |
| 214449 | - 2F6 - Other (please specify)
| - 2.G.1.a - Manufacture of Electrical Equipment
| | 2006 IPCC default | Manufacturing Emission Factor for Emissions from Electrical Equipment (Emission Factor for Manufacturing Phase) | Sealed Pressure Electrical Equipment (MV Switchgear) [MV Switchgear = Medium Voltage Switchgear for rated operating voltages above 1000 Volts and up to 52000 Volts; Based on technologies and practices in place in 1995 | | Japan | No mitigation measures implemented | | 0.29 | fraction [amount of gas emitted per amount of gas consumed] | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.2) | |
| 214450 | - 2F6 - Other (please specify)
| - 2.G.1.b - Use of Electrical Equipment
| | 2006 IPCC default | Equipment Use Emission Factor for Emissions from Electrical Equipment (Emission Factor for Use Phase) | Sealed Pressure Electrical Equipment (MV Switchgear) [MV Switchgear = Medium Voltage Switchgear for rated operating voltages above 1000 Volts and up to 52000 Volts; Based on technologies and practices in place in 1995 | | Japan | No mitigation measures implemented | | 0.007 | fraction [amount of gas emitted per year per nameplate capacity of all equipment | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.2) | |
| 214451 | - 2F6 - Other (please specify)
| - 2.G.1.c - Disposal of Electrical Equipment
| | 2006 IPCC default | Fraction of Charge Remaining at Retirement (Emission Factor for Disposal Phase), and Lifetime of Equipment | Sealed Pressure Electrical Equipment (MV Switchgear) [MV Switchgear = Medium Voltage Switchgear for rated operating voltages above 1000 Volts and up to 52000 Volts; Based on technologies and practices in place in 1995 | | Japan | No mitigation measures implemented | | 0.95 [Lifetime: Unknown (Not Reported)] | fraction [amount of gas emitted per nameplate capacity of all equipment installe | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.2) | |
| 214452 | - 2F6 - Other (please specify)
| - 2.G.1.a - Manufacture of Electrical Equipment
| | 2006 IPCC default | Manufacturing Emission Factor for Emissions from Electrical Equipment (Emission Factor for Manufacturing Phase) | Closed Pressure Electrical Equipment (HV Switchgear) [HV Switchgear = High Voltage Switchgear for rated operating voltages above 52000 Volts; Based on technologies and practices in place in 1995 | | Europe | No mitigation measures implemented | | 0.085 | fraction [amount of gas emitted per amount of gas consumed] | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.3) | |
| 214453 | - 2F6 - Other (please specify)
| - 2.G.1.b - Use of Electrical Equipment
| | 2006 IPCC default | Equipment Use Emission Factor for Emissions from Electrical Equipment (Emission Factor for Use Phase) | Closed Pressure Electrical Equipment (HV Switchgear) [HV Switchgear = High Voltage Switchgear for rated operating voltages above 52000 Volts; Based on technologies and practices in place in 1995 | | Europe | No mitigation measures implemented | | 0.026 | fraction [amount of gas emitted per year per nameplate capacity of all equipment | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.3) | |
| 214454 | - 2F6 - Other (please specify)
| - 2.G.1.c - Disposal of Electrical Equipment
| | 2006 IPCC default | Fraction of Charge Remaining at Retirement (Emission Factor for Disposal Phase), and Lifetime of Equipment | Closed Pressure Electrical Equipment (HV Switchgear) [HV Switchgear = High Voltage Switchgear for rated operating voltages above 52000 Volts; Based on technologies and practices in place in 1995 | | Europe | No mitigation measures implemented | | 0.95 [Lifetime: >35 years] | fraction [amount of gas emitted per nameplate capacity of all equipment installe | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.3) | |
| 214455 | - 2F6 - Other (please specify)
| - 2.G.1.a - Manufacture of Electrical Equipment
| | 2006 IPCC default | Manufacturing Emission Factor for Emissions from Electrical Equipment (Emission Factor for Manufacturing Phase) | Closed Pressure Electrical Equipment (HV Switchgear) [HV Switchgear = High Voltage Switchgear for rated operating voltages above 52000 Volts; Based on technologies and practices in place in 1995 | | Japan | No mitigation measures implemented | | 0.29 | fraction [amount of gas emitted per amount of gas consumed] | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.3) | |
| 214456 | - 2F6 - Other (please specify)
| - 2.G.1.b - Use of Electrical Equipment
| | 2006 IPCC default | Equipment Use Emission Factor for Emissions from Electrical Equipment (Emission Factor for Use Phase) | Closed Pressure Electrical Equipment (HV Switchgear) [HV Switchgear = High Voltage Switchgear for rated operating voltages above 52000 Volts; Based on technologies and practices in place in 1995 | | Japan | No mitigation measures implemented | | 0.007 | fraction [amount of gas emitted per year per nameplate capacity of all equipment | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.3) | |
| 214457 | - 2F6 - Other (please specify)
| - 2.G.1.c - Disposal of Electrical Equipment
| | 2006 IPCC default | Fraction of Charge Remaining at Retirement (Emission Factor for Disposal Phase), and Lifetime of Equipment | Closed Pressure Electrical Equipment (HV Switchgear) [HV Switchgear = High Voltage Switchgear for rated operating voltages above 52000 Volts; Based on technologies and practices in place in 1995 | | Japan | No mitigation measures implemented | | 0.95 [Lifetime: Unknown (Not Reported)] | fraction [amount of gas emitted per nameplate capacity of all equipment installe | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.3) | |
| 214458 | - 2F6 - Other (please specify)
| - 2.G.1.b - Use of Electrical Equipment
| | 2006 IPCC default | Equipment Use Emission Factor for Emissions from Electrical Equipment (Emission Factor for Use Phase) | Closed Pressure Electrical Equipment (HV Switchgear) [HV Switchgear = High Voltage Switchgear for rated operating voltages above 52000 Volts; Based on technologies and practices in place in 1995 | | United States of America | No mitigation measures implemented | | 0.14 | fraction [amount of gas emitted per nameplate capacity of all equipment installe | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.3) | |
| 214459 | - 2F6 - Other (please specify)
| - 2.G.1.a - Manufacture of Electrical Equipment
| | 2006 IPCC default | Manufacturing Emission Factor for Emissions from Electrical Equipment (Emission Factor for Manufacturing Phase) | Gas Insulated Transformers (GIT); Based on technologies and practices in place in 1995 | | Japan | No mitigation measures implemented | | 0.29 | fraction [amount of gas emitted per amount of gas consumed] | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.4) | |
| 214460 | - 2F6 - Other (please specify)
| - 2.G.1.b - Use of Electrical Equipment
| | 2006 IPCC default | Equipment Use Emission Factor for Emissions from Electrical Equipment (Emission Factor for Use Phase) | Gas Insulated Transformers (GIT); Based on technologies and practices in place in 1995 | | Japan | No mitigation measures implemented | | 0.007 | fraction [amount of gas emitted per year per nameplate capacity of all equipment | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.4) | |
| 214461 | - 2F6 - Other (please specify)
| - 2.G.1.c - Disposal of Electrical Equipment
| | 2006 IPCC default | Fraction of Charge Remaining at Retirement (Emission Factor for Disposal Phase), and Lifetime of Equipment | Gas Insulated Transformers (GIT); Based on technologies and practices in place in 1995 | | Japan | No mitigation measures implemented | | 0.95 [Lifetime: Unknown (Not Reported)] | fraction [amount of gas emitted per nameplate capacity of all equipment installe | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.4) | |
| 214462 | - 2F6 - Other (please specify)
| - 2.G.2.a - Military Applications
| | 2006 IPCC default | Emission Factor for SF6 Emissions from AWACS | Airborne Warning and Control System (AWACS) | | | | | 740 | kg/plane/year | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.7) | |
| 214463 | - 2F6 - Other (please specify)
| | | 2006 IPCC default | SF6 Use Factor for Calculation of SF6 Emissions from Particle Accelerators [Fraction of university and research particle accelerators that use SF6 as an insulator] | University and Research Particle Accelerator | | | | | 0.33 | fraction | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Page 8.28) | |
| 214464 | - 2F6 - Other (please specify)
| | | 2006 IPCC default | SF6 Charge Factor for Calculation of SF6 Emissions from Particle Accelerators [Average SF6 charge in an accelerator] | University and Research Particle Accelerator | | | | | 2400 | kg/accelerator | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Page 8.28) | |
| 214465 | - 2F6 - Other (please specify)
| | | 2006 IPCC default | Emission Factor for SF6 Emissions from Particle Accelerators | University and Research Particle Accelerator | | | | | 0.07 | fraction | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Page 8.28) | |