| Active Filters |
| | | | | | | | | | | | | |
| 214446 | - 2F6 - Other (please specify)
| - 2.G.1.a - Manufacture of Electrical Equipment
| | 2006 IPCC default | Manufacturing Emission Factor for Emissions from Electrical Equipment (Emission Factor for Manufacturing Phase) | Sealed Pressure Electrical Equipment (MV Switchgear) [MV Switchgear = Medium Voltage Switchgear for rated operating voltages above 1000 Volts and up to 52000 Volts; Based on technologies and practices in place in 1995 | | Europe | No mitigation measures implemented | | 0.07 | fraction [amount of gas emitted per amount of gas consumed] | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.2) | |
| 214447 | - 2F6 - Other (please specify)
| - 2.G.1.b - Use of Electrical Equipment
| | 2006 IPCC default | Equipment Use Emission Factor for Emissions from Electrical Equipment (Emission Factor for Use Phase) | Sealed Pressure Electrical Equipment (MV Switchgear) [MV Switchgear = Medium Voltage Switchgear for rated operating voltages above 1000 Volts and up to 52000 Volts; Based on technologies and practices in place in 1995 | | Europe | No mitigation measures implemented | | 0.002 | fraction [amount of gas emitted per year per nameplate capacity of all equipment | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.2) | |
| 214448 | - 2F6 - Other (please specify)
| - 2.G.1.c - Disposal of Electrical Equipment
| | 2006 IPCC default | Fraction of Charge Remaining at Retirement (Emission Factor for Disposal Phase), and Lifetime of Equipment | Sealed Pressure Electrical Equipment (MV Switchgear) [MV Switchgear = Medium Voltage Switchgear for rated operating voltages above 1000 Volts and up to 52000 Volts; Based on technologies and practices in place in 1995 | | Europe | No mitigation measures implemented | | 0.93 [Lifetime: >35 years] | fraction [amount of gas emitted per nameplate capacity of all equipment installe | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.2) | |
| 214449 | - 2F6 - Other (please specify)
| - 2.G.1.a - Manufacture of Electrical Equipment
| | 2006 IPCC default | Manufacturing Emission Factor for Emissions from Electrical Equipment (Emission Factor for Manufacturing Phase) | Sealed Pressure Electrical Equipment (MV Switchgear) [MV Switchgear = Medium Voltage Switchgear for rated operating voltages above 1000 Volts and up to 52000 Volts; Based on technologies and practices in place in 1995 | | Japan | No mitigation measures implemented | | 0.29 | fraction [amount of gas emitted per amount of gas consumed] | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.2) | |
| 214450 | - 2F6 - Other (please specify)
| - 2.G.1.b - Use of Electrical Equipment
| | 2006 IPCC default | Equipment Use Emission Factor for Emissions from Electrical Equipment (Emission Factor for Use Phase) | Sealed Pressure Electrical Equipment (MV Switchgear) [MV Switchgear = Medium Voltage Switchgear for rated operating voltages above 1000 Volts and up to 52000 Volts; Based on technologies and practices in place in 1995 | | Japan | No mitigation measures implemented | | 0.007 | fraction [amount of gas emitted per year per nameplate capacity of all equipment | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.2) | |
| 214451 | - 2F6 - Other (please specify)
| - 2.G.1.c - Disposal of Electrical Equipment
| | 2006 IPCC default | Fraction of Charge Remaining at Retirement (Emission Factor for Disposal Phase), and Lifetime of Equipment | Sealed Pressure Electrical Equipment (MV Switchgear) [MV Switchgear = Medium Voltage Switchgear for rated operating voltages above 1000 Volts and up to 52000 Volts; Based on technologies and practices in place in 1995 | | Japan | No mitigation measures implemented | | 0.95 [Lifetime: Unknown (Not Reported)] | fraction [amount of gas emitted per nameplate capacity of all equipment installe | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.2) | |
| 214452 | - 2F6 - Other (please specify)
| - 2.G.1.a - Manufacture of Electrical Equipment
| | 2006 IPCC default | Manufacturing Emission Factor for Emissions from Electrical Equipment (Emission Factor for Manufacturing Phase) | Closed Pressure Electrical Equipment (HV Switchgear) [HV Switchgear = High Voltage Switchgear for rated operating voltages above 52000 Volts; Based on technologies and practices in place in 1995 | | Europe | No mitigation measures implemented | | 0.085 | fraction [amount of gas emitted per amount of gas consumed] | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.3) | |
| 214453 | - 2F6 - Other (please specify)
| - 2.G.1.b - Use of Electrical Equipment
| | 2006 IPCC default | Equipment Use Emission Factor for Emissions from Electrical Equipment (Emission Factor for Use Phase) | Closed Pressure Electrical Equipment (HV Switchgear) [HV Switchgear = High Voltage Switchgear for rated operating voltages above 52000 Volts; Based on technologies and practices in place in 1995 | | Europe | No mitigation measures implemented | | 0.026 | fraction [amount of gas emitted per year per nameplate capacity of all equipment | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.3) | |
| 214454 | - 2F6 - Other (please specify)
| - 2.G.1.c - Disposal of Electrical Equipment
| | 2006 IPCC default | Fraction of Charge Remaining at Retirement (Emission Factor for Disposal Phase), and Lifetime of Equipment | Closed Pressure Electrical Equipment (HV Switchgear) [HV Switchgear = High Voltage Switchgear for rated operating voltages above 52000 Volts; Based on technologies and practices in place in 1995 | | Europe | No mitigation measures implemented | | 0.95 [Lifetime: >35 years] | fraction [amount of gas emitted per nameplate capacity of all equipment installe | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.3) | |
| 214455 | - 2F6 - Other (please specify)
| - 2.G.1.a - Manufacture of Electrical Equipment
| | 2006 IPCC default | Manufacturing Emission Factor for Emissions from Electrical Equipment (Emission Factor for Manufacturing Phase) | Closed Pressure Electrical Equipment (HV Switchgear) [HV Switchgear = High Voltage Switchgear for rated operating voltages above 52000 Volts; Based on technologies and practices in place in 1995 | | Japan | No mitigation measures implemented | | 0.29 | fraction [amount of gas emitted per amount of gas consumed] | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.3) | |
| 214456 | - 2F6 - Other (please specify)
| - 2.G.1.b - Use of Electrical Equipment
| | 2006 IPCC default | Equipment Use Emission Factor for Emissions from Electrical Equipment (Emission Factor for Use Phase) | Closed Pressure Electrical Equipment (HV Switchgear) [HV Switchgear = High Voltage Switchgear for rated operating voltages above 52000 Volts; Based on technologies and practices in place in 1995 | | Japan | No mitigation measures implemented | | 0.007 | fraction [amount of gas emitted per year per nameplate capacity of all equipment | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.3) | |
| 214457 | - 2F6 - Other (please specify)
| - 2.G.1.c - Disposal of Electrical Equipment
| | 2006 IPCC default | Fraction of Charge Remaining at Retirement (Emission Factor for Disposal Phase), and Lifetime of Equipment | Closed Pressure Electrical Equipment (HV Switchgear) [HV Switchgear = High Voltage Switchgear for rated operating voltages above 52000 Volts; Based on technologies and practices in place in 1995 | | Japan | No mitigation measures implemented | | 0.95 [Lifetime: Unknown (Not Reported)] | fraction [amount of gas emitted per nameplate capacity of all equipment installe | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.3) | |
| 214458 | - 2F6 - Other (please specify)
| - 2.G.1.b - Use of Electrical Equipment
| | 2006 IPCC default | Equipment Use Emission Factor for Emissions from Electrical Equipment (Emission Factor for Use Phase) | Closed Pressure Electrical Equipment (HV Switchgear) [HV Switchgear = High Voltage Switchgear for rated operating voltages above 52000 Volts; Based on technologies and practices in place in 1995 | | United States of America | No mitigation measures implemented | | 0.14 | fraction [amount of gas emitted per nameplate capacity of all equipment installe | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.3) | |
| 214459 | - 2F6 - Other (please specify)
| - 2.G.1.a - Manufacture of Electrical Equipment
| | 2006 IPCC default | Manufacturing Emission Factor for Emissions from Electrical Equipment (Emission Factor for Manufacturing Phase) | Gas Insulated Transformers (GIT); Based on technologies and practices in place in 1995 | | Japan | No mitigation measures implemented | | 0.29 | fraction [amount of gas emitted per amount of gas consumed] | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.4) | |
| 214460 | - 2F6 - Other (please specify)
| - 2.G.1.b - Use of Electrical Equipment
| | 2006 IPCC default | Equipment Use Emission Factor for Emissions from Electrical Equipment (Emission Factor for Use Phase) | Gas Insulated Transformers (GIT); Based on technologies and practices in place in 1995 | | Japan | No mitigation measures implemented | | 0.007 | fraction [amount of gas emitted per year per nameplate capacity of all equipment | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.4) | |
| 214461 | - 2F6 - Other (please specify)
| - 2.G.1.c - Disposal of Electrical Equipment
| | 2006 IPCC default | Fraction of Charge Remaining at Retirement (Emission Factor for Disposal Phase), and Lifetime of Equipment | Gas Insulated Transformers (GIT); Based on technologies and practices in place in 1995 | | Japan | No mitigation measures implemented | | 0.95 [Lifetime: Unknown (Not Reported)] | fraction [amount of gas emitted per nameplate capacity of all equipment installe | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.4) | |
| 225367 | - 2F6 - Other (please specify)
| - 2.G.1 - Electrical Equipment
| | Other (e.g. compiled) | Annual losses (operation and disposal) of SF6 in electrical equipment | Electricity supply and distribution equipment (circuit breakers, switchgear and control gear) | | Australia | | Years: 2010-2018 | 0.0040-0088 | t SF6/t national stock of SF6 in electrical equipment | National Inventory Report (Annex I) | |
| 225426 | - 2F6 - Other (please specify)
| - 2.G.1.b - Use of Electrical Equipment
| | Other (e.g. compiled) | SF6 leakage rate from sealed pressure (medium voltage) switchgears | SF6 is used for electrical insulation and current interruption in medium voltage (MV) switchgear equipment used in the transmission and distribution of electricity. | The emission factor provided herewith only covers the leakage of SF6 during operating life and do not cover emissions during major failures/arc faults or maintenance losses. | | | | 0.1 | % per year | Other | |
| 225427 | - 2F6 - Other (please specify)
| - 2.G.1.b - Use of Electrical Equipment
| | Other (e.g. compiled) | SF6 leakage rate from closed pressure (high voltage) switchgears (filled with pure SF6) | SF6 is used for electrical insulation and current interruption in high voltage (HV) switchgear equipment used in the transmission and distribution of electricity. | The emission factor provided herewith only covers the leakage of SF6 during operating life and do not cover emissions during major failures/arc faults or maintenance losses. | | | | 0.5 | % per year | Other | |
| 225428 | - 2F6 - Other (please specify)
| - 2.G.1.b - Use of Electrical Equipment
| | Other (e.g. compiled) | SF6 leakage rate from closed pressure (high voltage) switchgears (will with SF6 mixtures) | SF6 is used for electrical insulation and current interruption in high voltage (HV) switchgear equipment used in the transmission and distribution of electricity. | The emission factor provided herewith only covers the leakage of SF6 during operating life and do not cover emissions during major failures/arc faults or maintenance losses. | | | | 1 | % per year | Other | |