| Active Filters |
| | | | | | | | | | | | | |
| 214446 | - 2F6 - Other (please specify)
| - 2.G.1.a - Manufacture of Electrical Equipment
| | 2006 IPCC default | Manufacturing Emission Factor for Emissions from Electrical Equipment (Emission Factor for Manufacturing Phase) | Sealed Pressure Electrical Equipment (MV Switchgear) [MV Switchgear = Medium Voltage Switchgear for rated operating voltages above 1000 Volts and up to 52000 Volts; Based on technologies and practices in place in 1995 | | Europe | No mitigation measures implemented | | 0.07 | fraction [amount of gas emitted per amount of gas consumed] | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.2) | |
| 214449 | - 2F6 - Other (please specify)
| - 2.G.1.a - Manufacture of Electrical Equipment
| | 2006 IPCC default | Manufacturing Emission Factor for Emissions from Electrical Equipment (Emission Factor for Manufacturing Phase) | Sealed Pressure Electrical Equipment (MV Switchgear) [MV Switchgear = Medium Voltage Switchgear for rated operating voltages above 1000 Volts and up to 52000 Volts; Based on technologies and practices in place in 1995 | | Japan | No mitigation measures implemented | | 0.29 | fraction [amount of gas emitted per amount of gas consumed] | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.2) | |
| 214452 | - 2F6 - Other (please specify)
| - 2.G.1.a - Manufacture of Electrical Equipment
| | 2006 IPCC default | Manufacturing Emission Factor for Emissions from Electrical Equipment (Emission Factor for Manufacturing Phase) | Closed Pressure Electrical Equipment (HV Switchgear) [HV Switchgear = High Voltage Switchgear for rated operating voltages above 52000 Volts; Based on technologies and practices in place in 1995 | | Europe | No mitigation measures implemented | | 0.085 | fraction [amount of gas emitted per amount of gas consumed] | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.3) | |
| 214455 | - 2F6 - Other (please specify)
| - 2.G.1.a - Manufacture of Electrical Equipment
| | 2006 IPCC default | Manufacturing Emission Factor for Emissions from Electrical Equipment (Emission Factor for Manufacturing Phase) | Closed Pressure Electrical Equipment (HV Switchgear) [HV Switchgear = High Voltage Switchgear for rated operating voltages above 52000 Volts; Based on technologies and practices in place in 1995 | | Japan | No mitigation measures implemented | | 0.29 | fraction [amount of gas emitted per amount of gas consumed] | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.3) | |
| 214459 | - 2F6 - Other (please specify)
| - 2.G.1.a - Manufacture of Electrical Equipment
| | 2006 IPCC default | Manufacturing Emission Factor for Emissions from Electrical Equipment (Emission Factor for Manufacturing Phase) | Gas Insulated Transformers (GIT); Based on technologies and practices in place in 1995 | | Japan | No mitigation measures implemented | | 0.29 | fraction [amount of gas emitted per amount of gas consumed] | 2006 IPCC Guidelines for National Greenhouse Gas Inventories (Volume 3, Chapter 8, Table 8.4) | |